Differential Pressure Transmitter, P26
Price And Quantity
- Piece/Pieces
- 1
- Piece/Pieces
- 96900 INR
Product Specifications
- 6 mm hose connection
- Electrical
- +- 2% or +- 0.5% of max. value %
- 24 VAC / DC, 10%, 24 VAC, +6% with galvanic isolation, 230/115 VAC, -15% Volt (v)
- 10 /50 / 100 / 250 / 500 Pa 1 / 2.5 / 5 / 10 / 20 / 50 / 100 kPa Pa
- 750 g Grams (g)
- pressure monitoring in clean rooms, laboratories, pharmaceutical plants, operating theaters
- 6 VA Volt (v)
- measuring pressure in neutral fluids and non-aggressive gases.
Product Description
Differential pressure transmitter with scalable measuring range and a high level of overpressure protection
Special Features:
Special Features:
- High level of accuracy and long-term stability through automatic zero-point calibration
- Measurement of differential pressure or volumetric flow / flow rate possible
- Easy configuration of the measuring range, analog output, time constants and units via PC or keyboard (optional)
- USB interface (optional)
- Display with keyboard for configuration of the pressure transmitter (optional)
- Multilingual menu (English/German/Italian/French)
- Suitable for top-hat rail mounting and wall surface installation
- 2 floating switching relays (optional)
- Integrated power adapter for 115/230 VAC power supply
- Silicon-free materials for parts in contact with medium
- Output signal can be configured 0-10 V, 0/4-20 mA or ñ 5 V
- Selectable attenuation of the output signal from 0-60 s
- Can be calibrated
- Highly stable measurements thanks to cyclical self-calibration of the zero point
- High level of overpressure protection even in the smallest measuring ranges
Â
Specification
Pressure Ports
For tubing NW 6 mm
Range
10/50/100/250/500 Pa
1 / 2.5 / 5/10/20/50/100 kPa
Usage/Application
Monitoring of gaseous, non-combustible and non-aggressive media.
Model Name/Number
P26
Brand
Halstrup Walcher
Process Temperature
10 to +50Degree C
Accuracy
+- 2% or +- 0.5% of max. value
Output
Analogue (4 to 20 mA, 0 to 20mA, 0 to 10 V,
-5 to 5 V)
Sensor response Time
25msâ¦.40s (Adjustable)
Supply Voltage
24 VAC / DC, ñ 10%, 24 VAC, +6% with galvanic isolation, 230/115 VAC, -15%
Switch Contact
2 relays with potential-free changeover contacts 230 VAC (50/60 Hz)
Scalable Range
Freely scalable from 10 .. 100% within a measuring range
Overload Capacity
400 kPa
Temperature Coefficient span
0.03 % of max value
Protection Class
IP65